Sinamics S110
Approved changes feed: RSS · Atom
cpe:2.3:a:siemens:sinamics_s110:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Sinamics S110 (0af652ad-29d9-5730-a31e-18150b110af0) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2025-40833 |
vulnerable | 2026-06-08 07:25:06.207222 |
Details available
HIGH (7.5)
The affected devices contain a null pointer dereference vulnerability while processing specially crafted IPv4 requests. This could allow an attacker to cause denial of service condition. A manual restart is required to recover the system.
Published: 2026-05-12T08:20:46.879Z
Updated: 2026-07-14T09:19:07.571Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-25622 |
vulnerable | 2026-06-08 05:41:46.129520 |
Details available
MEDIUM (5.3)
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.
This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
Published: 2022-04-12T00:00:00.000Z
Updated: 2025-04-21T13:54:36.799Z |
Imported from gcve-enriched-dumps CVE data |