Approved changes feed: RSS · Atom

cpe:2.3:a:schneider_electric:clipsal_c-bus_network_automation_controller,_5500nac:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorSchneider Electric (90ae6a25-22b7-5d12-ba01-612e2f9226a5)
ProductClipsal C Bus Network Automation Controller, 5500Nac (f7593703-447b-5384-b519-0e2dbd9f8dc3)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2022-32514 vulnerable 2026-06-08 05:44:44.903223 Details available
CRITICAL (9.8)
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
Published: 2023-01-30T00:00:00.000Z
Updated: 2025-02-05T20:18:27.254Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-32513 vulnerable 2026-06-08 05:44:44.887827 Details available
CRITICAL (9.8)
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
Published: 2023-01-30T00:00:00.000Z
Updated: 2025-02-05T20:18:33.992Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.