5500Nac Firmware
Approved changes feed: RSS · Atom
cpe:2.3:o:schneider-electric:5500nac_firmware:*:*:*:*:*:*:*:*
part: o version: * update: *
| Vendor | Schneider Electric (e6a779d5-aeb8-5b94-be36-761d5c05741c) |
|---|---|
| Product | 5500Nac Firmware (26215223-95a3-59a8-b14c-f5bbbcc5e1e2) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2022-32514 |
vulnerable | 2026-06-08 05:44:44.903662 |
Details available
CRITICAL (9.8)
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
Published: 2023-01-30T00:00:00.000Z
Updated: 2025-02-05T20:18:27.254Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-32513 |
vulnerable | 2026-06-08 05:44:44.896273 |
Details available
CRITICAL (9.8)
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
Published: 2023-01-30T00:00:00.000Z
Updated: 2025-02-05T20:18:33.992Z |
Imported from gcve-enriched-dumps CVE data |
Contribute