Approved changes feed: RSS · Atom

cpe:2.3:o:omron:nx1p2-1040dt_firmware:*:*:*:*:*:*:*:*

part: o version: * update: *

VendorOmron (675649e9-6a71-548a-9a9b-e097b9db785b)
ProductNx1P2 1040Dt Firmware (b54dca0a-34b8-5048-9cb0-5df0ee7c1bfd)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2024-33687 vulnerable 2026-06-08 06:37:32.055408 Details available
Insufficient verification of data authenticity issue exists in NJ Series CPU Unit all versions and NX Series CPU Unit all versions. If a user program in the affected product is altered, the product may not be able to detect the alteration.
Published: 2024-06-24T15:03:05.467Z
Updated: 2025-03-13T14:36:56.825Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-34151 vulnerable 2026-06-08 05:44:52.207666 Details available
Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller.
Published: 2022-07-04T01:51:00.000Z
Updated: 2026-06-02T19:47:10.923Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-33971 vulnerable 2026-06-08 05:44:51.916178 Details available
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication between the controller and the specific software used by OMRON internally to cause a denial-of-service (DoS) condition or execute a malicious program.
Published: 2022-07-04T01:50:54.000Z
Updated: 2026-06-02T19:44:14.367Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-33208 vulnerable 2026-06-08 05:44:46.521983 Details available
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software 'Sysmac Studio' and/or a Programmable Terminal (PT) to access the controller.
Published: 2022-07-04T01:50:44.000Z
Updated: 2024-08-03T08:01:20.422Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.