Approved changes feed: RSS · Atom

cpe:2.3:a:siemens:mendix_saml_(mendix_9_compatible,_upgrade_track):*:*:*:*:*:*:*:*

part: a version: * update: *

VendorSiemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f)
ProductMendix Saml (Mendix 9 Compatible, Upgrade Track) (8764785b-72e2-5442-bebf-3e23c7242517)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2022-46823 vulnerable 2026-06-08 05:50:39.509083 Details available
CRITICAL (9.3)
A vulnerability has been identified in Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.4), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.0 < V3.3.9), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.8). The affected module is vulnerable to reflected cross-site scripting (XSS) attacks. This could allow an attacker to extract sensitive information by tricking users into accessing a malicious link.
Published: 2023-01-10T11:39:46.211Z
Updated: 2025-04-09T14:01:27.985Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-44457 vulnerable 2026-06-08 05:49:35.563943 Details available
A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.0 < V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.1 < V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration.
Published: 2022-11-08T00:00:00.000Z
Updated: 2025-05-01T18:07:21.381Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-37011 vulnerable 2026-06-08 05:46:08.323880 Details available
A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0). Affected versions of the module insufficiently protect from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. For compatibility reasons, fix versions still contain this issue, but only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled.
Published: 2022-09-13T00:00:00.000Z
Updated: 2024-08-03T10:21:32.435Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.