Simatic Pcs Neo V4.0
Approved changes feed: RSS · Atom
cpe:2.3:a:siemens:simatic_pcs_neo_v4.0:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Siemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f) |
|---|---|
| Product | Simatic Pcs Neo V4.0 (d933fc9a-f1af-55e7-9680-ed0a68610cd5) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2024-49775 |
vulnerable | 2026-06-08 06:50:14.665916 |
Details available
CRITICAL (9.8)
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component.
This could allow an unauthenticated remote attacker to execute arbitrary code.
Published: 2024-12-16T15:06:04.714Z
Updated: 2026-01-13T09:43:48.714Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2024-45386 |
vulnerable | 2026-06-08 06:48:06.011581 |
Details available
HIGH (8.8)
A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SIMOCODE ES V19 (All versions < V19 Update 1), SIRIUS Safety ES V19 (TIA Portal) (All versions < V19 Update 1), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions < V19 Update 1), TIA Administrator (All versions < V3.0.4). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout.
Published: 2025-02-11T10:28:44.675Z
Updated: 2025-02-11T14:38:30.854Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2024-33698 |
vulnerable | 2026-06-08 06:37:32.107447 |
Details available
CRITICAL (9.8)
A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
Published: 2024-09-10T09:36:31.009Z
Updated: 2025-10-14T09:15:00.448Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-28831 |
vulnerable | 2026-06-08 06:02:36.243672 |
Details available
HIGH (7.5)
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation.
This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
Published: 2023-09-12T09:32:06.153Z
Updated: 2025-11-11T20:20:09.380Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-45147 |
vulnerable | 2026-06-08 05:50:35.812353 |
Details available
HIGH (7.8)
A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
Published: 2024-07-09T12:04:22.545Z
Updated: 2025-08-27T20:32:52.249Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.