Approved changes feed: RSS · Atom

cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:machine:*:*:*

part: a version: * update: *

VendorRockwellautomation (483fb14e-bfe0-5dc5-b460-aca202063cba)
ProductFactorytalk View (090552bd-437f-5666-9a3f-e3987aa07682)
Edition*
Language*
Software editionmachine
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2025-9064 vulnerable 2026-06-08 07:45:21.648628 Rockwell Automation FactoryTalk View Machine Edition Path Traversal
A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.
Published: 2025-10-14T12:22:36.551Z
Updated: 2025-10-14T18:46:34.339Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-9063 vulnerable 2026-06-08 07:45:21.646983 Rockwell Automation PanelView Plus 7 Performance Series B Authentication Bypass
An authentication bypass security issue exists within FactoryTalk View Machine Edition Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more.
Published: 2025-10-14T12:20:39.318Z
Updated: 2025-10-14T18:45:57.209Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-21914 vulnerable 2026-06-08 06:29:32.609899 Rockwell Automation - FactoryTalk® View ME on PanelView™ Plus 7 Boot Terminal lack Security Protections
MEDIUM (5.3)
A vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView™ Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView™ product.
Published: 2024-03-25T21:27:18.975Z
Updated: 2024-08-05T16:36:55.604Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-2071 vulnerable 2026-06-08 06:02:41.367724 FactoryTalk View Machine Edition Vulnerable to Remote Code Execution
CRITICAL (9.8)
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets.  The device has the functionality, through a CIP class, to execute exported functions from libraries.  There is a routine that restricts it to execute specific functions from two dynamic link library files.  By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.
Published: 2023-09-12T13:12:42.386Z
Updated: 2024-09-25T20:05:52.107Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute