cpe:2.3:o:siemens:cpci85_firmware:*:*:*:*:*:*:*:*

part: o version: * update: *

VendorSiemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f)
ProductCpci85 Firmware (4326de8d-7d3d-5ea6-ac7e-6a3478d900b7)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2024-37998 vulnerable 2026-06-08 06:39:48.740179 Details available
CRITICAL (9.8)
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). The password of administrative accounts of the affected applications can be reset without requiring the knowledge of the current password, given the auto login is enabled. This could allow an unauthorized attacker to obtain administrative access of the affected applications.
Published: 2024-07-22T13:54:49.501Z
Updated: 2024-08-02T04:04:24.632Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-31485 vulnerable 2026-06-08 06:35:31.698559 Details available
HIGH (7.2)
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Published: 2024-05-14T10:02:25.052Z
Updated: 2025-02-13T17:47:58.693Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-33921 vulnerable 2026-06-08 06:06:23.872621 Details available
MEDIUM (6.8)
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The affected devices contain an exposed UART console login interface. An attacker with direct physical access could try to bruteforce or crack the root password to login to the device.
Published: 2023-06-13T08:17:20.886Z
Updated: 2025-02-13T16:55:11.752Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-33920 vulnerable 2026-06-08 06:06:23.871981 Details available
MEDIUM (6.8)
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The affected devices contain the hash of the root password in a hard-coded form, which could be exploited for UART console login to the device. An attacker with direct physical access could exploit this vulnerability.
Published: 2023-06-13T08:17:19.819Z
Updated: 2025-02-13T16:55:11.191Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-33919 vulnerable 2026-06-08 06:06:23.871177 Details available
HIGH (7.2)
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.