Scada Data Gateway
Approved changes feed: RSS · Atom
cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*
part: a version: 5.1.3.20324 update: *
| Vendor | Trianglemicroworks (0b7b427a-71ef-59c0-bead-7644673035b6) |
|---|---|
| Product | Scada Data Gateway (c60347e8-f1db-5318-bfd8-30cdfc9a201f) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2023-39468 |
vulnerable | 2026-06-08 06:09:37.544805 |
Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability
HIGH (7.2)
Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.
The specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799.
Published: 2024-05-03T01:59:30.325Z
Updated: 2024-08-02T18:10:20.697Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-39467 |
vulnerable | 2026-06-08 06:09:37.544466 |
Triangle MicroWorks SCADA Data Gateway certificate Information Disclosure Vulnerability
MEDIUM (5.3)
Triangle MicroWorks SCADA Data Gateway certificate Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the configuration of certificate web directory. The issue results from the exposure of sensitive information in the application webroot. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20798.
Published: 2024-05-03T01:59:29.616Z
Updated: 2024-08-02T18:10:20.678Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-39466 |
vulnerable | 2026-06-08 06:09:37.543920 |
Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability
MEDIUM (5.3)
Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797.
Published: 2024-05-03T01:59:28.811Z
Updated: 2024-08-02T18:10:20.933Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-39465 |
vulnerable | 2026-06-08 06:09:37.543603 |
Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability
HIGH (7.5)
Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the TmwCrypto class. The issue results from the usage of a hard-coded cryptograhic key and the usage of a hard-coded certificate. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20615.
Published: 2024-05-03T01:59:28.085Z
Updated: 2024-08-02T18:10:21.061Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-39464 |
vulnerable | 2026-06-08 06:09:37.543026 |
Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability
HIGH (7.2)
Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.
Published: 2024-05-03T01:59:27.382Z
Updated: 2024-08-02T18:10:20.680Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-39463 |
vulnerable | 2026-06-08 06:09:37.542661 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-39462 |
vulnerable | 2026-06-08 06:09:37.542278 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-39461 |
vulnerable | 2026-06-08 06:09:37.541660 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-39460 |
vulnerable | 2026-06-08 06:09:37.540919 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-39458 |
vulnerable | 2026-06-08 06:09:37.536028 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2023-39457 |
vulnerable | 2026-06-08 06:09:37.534414 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.