Approved changes feed: RSS · Atom

cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*

part: a version: 5.1.3.20324 update: *

VendorTrianglemicroworks (0b7b427a-71ef-59c0-bead-7644673035b6)
ProductScada Data Gateway (c60347e8-f1db-5318-bfd8-30cdfc9a201f)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2023-39468 vulnerable 2026-06-08 06:09:37.544805 Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability
HIGH (7.2)
Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability. The specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799.
Published: 2024-05-03T01:59:30.325Z
Updated: 2024-08-02T18:10:20.697Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-39467 vulnerable 2026-06-08 06:09:37.544466 Triangle MicroWorks SCADA Data Gateway certificate Information Disclosure Vulnerability
MEDIUM (5.3)
Triangle MicroWorks SCADA Data Gateway certificate Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of certificate web directory. The issue results from the exposure of sensitive information in the application webroot. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20798.
Published: 2024-05-03T01:59:29.616Z
Updated: 2024-08-02T18:10:20.678Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-39466 vulnerable 2026-06-08 06:09:37.543920 Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability
MEDIUM (5.3)
Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797.
Published: 2024-05-03T01:59:28.811Z
Updated: 2024-08-02T18:10:20.933Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-39465 vulnerable 2026-06-08 06:09:37.543603 Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability
HIGH (7.5)
Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the TmwCrypto class. The issue results from the usage of a hard-coded cryptograhic key and the usage of a hard-coded certificate. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20615.
Published: 2024-05-03T01:59:28.085Z
Updated: 2024-08-02T18:10:21.061Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-39464 vulnerable 2026-06-08 06:09:37.543026 Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability
HIGH (7.2)
Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.
Published: 2024-05-03T01:59:27.382Z
Updated: 2024-08-02T18:10:20.680Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-39463 vulnerable 2026-06-08 06:09:37.542661 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-39462 vulnerable 2026-06-08 06:09:37.542278 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-39461 vulnerable 2026-06-08 06:09:37.541660 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-39460 vulnerable 2026-06-08 06:09:37.540919 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-39458 vulnerable 2026-06-08 06:09:37.536028 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2023-39457 vulnerable 2026-06-08 06:09:37.534414 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.