cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:-:*:*:*:*:*:*:*

part: o version: - update: *

VendorRockwellautomation (483fb14e-bfe0-5dc5-b460-aca202063cba)
ProductMicrologix 1400 Firmware (bddb3d47-b530-528c-b9b4-894fd10cc4eb)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2022-46670 vulnerable 2026-06-08 05:50:39.139788 Rockwell Automation MicroLogix 1100 & 1400 Vulnerable to Cross-Site Scripting Attack
HIGH (7.1)
Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution.  The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website.
Published: 2022-12-16T20:12:22.414Z
Updated: 2025-04-17T14:35:29.173Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-3166 vulnerable 2026-06-08 05:47:19.603391 MicroLogix 1100 & 1400 Product Web Server Application Vulnerable to Denial-Of-Service Condition Attack
HIGH (7.5)
Rockwell Automation was made aware that the webservers of the Micrologix 1100 and 1400 controllers contain a vulnerability that may lead to a denial-of-service condition. The security vulnerability could be exploited by an attacker with network access to the affected systems by sending TCP packets to webserver and closing it abruptly which would cause a denial-of-service condition for the web server application on the device
Published: 2022-12-16T19:59:25.261Z
Updated: 2025-04-17T15:30:27.677Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2018-17924 vulnerable 2026-06-08 05:11:06.920948 Details available
Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address.
Published: 2018-12-07T14:00:00.000Z
Updated: 2026-06-03T13:43:39.921Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.