cpe:2.3:a:tenda:w9:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorTenda (cebb1c0a-7ddd-5bf6-9fc6-52b2b4f8dd42)
ProductW9 (097db08f-7bcc-5d5d-9021-35b004b7ad61)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2024-4244 vulnerable 2026-06-08 06:50:17.289386 Tenda W9 DhcpSetSer fromDhcpSetSer stack-based overflow
HIGH (8.8)
A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Published: 2024-04-26T21:31:06.054Z
Updated: 2024-08-01T20:33:53.169Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-4243 vulnerable 2026-06-08 06:50:17.288808 Tenda W9 wifiSSIDset formwrlSSIDset stack-based overflow
HIGH (8.8)
A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Published: 2024-04-26T21:31:04.545Z
Updated: 2024-08-01T20:33:53.084Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-4242 vulnerable 2026-06-08 06:50:17.288213 Tenda W9 wifiSSIDget formwrlSSIDget stack-based overflow
HIGH (8.8)
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Published: 2024-04-26T21:00:06.782Z
Updated: 2024-08-01T20:33:53.182Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-4241 vulnerable 2026-06-08 06:50:17.287632 Tenda W9 formQosManageDouble_auto stack-based overflow
HIGH (8.8)
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Published: 2024-04-26T21:00:05.152Z
Updated: 2024-08-01T20:33:53.022Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-4240 vulnerable 2026-06-08 06:50:17.286227 Tenda W9 formQosManageDouble_user stack-based overflow
HIGH (8.8)
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Published: 2024-04-26T20:31:06.864Z
Updated: 2024-08-01T20:33:52.939Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-0542 vulnerable 2026-06-08 06:22:01.313309 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-0541 vulnerable 2026-06-08 06:22:01.312814 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-0540 vulnerable 2026-06-08 06:22:01.312178 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-0539 vulnerable 2026-06-08 06:22:01.311534 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-0538 vulnerable 2026-06-08 06:22:01.310809 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-0537 vulnerable 2026-06-08 06:22:01.310043 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-0536 vulnerable 2026-06-08 06:22:01.306673 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.