Approved changes feed: RSS · Atom

cpe:2.3:o:sick:inspector62x_firmware:-:*:*:*:*:*:*:*

part: o version: - update: *

VendorSick (7f3a0778-9cb3-5791-a25c-ef23979e3fe0)
ProductInspector62X Firmware (425cb549-0365-5eeb-a126-42da995af920)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2024-10776 vulnerable 2026-06-08 06:23:47.506945 SICK InspectorP61x and SICK InspectorP62x: missing authentication
HIGH (8.2)
Lua apps can be deployed, removed, started, reloaded or stopped without authorization via AppManager. This allows an attacker to remove legitimate apps creating a DoS attack, read and write files or load apps that use all features of the product available to a customer.
Published: 2024-12-06T12:38:55.781Z
Updated: 2024-12-09T14:06:40.506Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-10774 vulnerable 2026-06-08 06:23:47.500634 SICK InspectorP61x and SICK InspectorP62x have unauthenticated CROWN APIs
HIGH (7.3)
Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication.
Published: 2024-12-06T12:35:03.327Z
Updated: 2024-12-09T14:48:43.228Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-10773 vulnerable 2026-06-08 06:23:47.500124 SICK InspectorP61x, SICK InspectorP62x and SICK TiM3xx are vulnerable for pass-the-hash attacks
CRITICAL (9)
The product is vulnerable to pass-the-hash attacks in combination with hardcoded credentials of hidden user levels. This means that an attacker can log in with the hidden user levels and gain full access to the device.
Published: 2024-12-06T12:31:10.776Z
Updated: 2024-12-09T14:44:36.597Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-10772 vulnerable 2026-06-08 06:23:47.499576 SICK InspectorP61x and SICK InspectorP62x are vulnerable for firmware modification
HIGH (8.8)
Since the firmware update is not validated, an attacker can install modified firmware on the device. This has a high impact on the availabilty, integrity and confidentiality up to the complete compromise of the device.
Published: 2024-12-06T12:28:56.564Z
Updated: 2024-12-09T14:46:03.214Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2024-10771 vulnerable 2026-06-08 06:23:47.493591 SICK InspectorP61x, SICK InspectorP62x and SICK TiM3xx are vulnerable for remote code execution
HIGH (8.8)
Due to missing input validation during one step of the firmware update process, the product is vulnerable to remote code execution. With network access and the user level ”Service”, an attacker can execute arbitrary system commands in the root user’s contexts.
Published: 2024-12-06T12:24:40.610Z
Updated: 2026-05-13T12:04:13.962Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute