Approved changes feed: RSS · Atom

cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:9.0:*:*:*:*:*:*:*

part: a version: 9.0 update: *

VendorSchneider Electric (e6a779d5-aeb8-5b94-be36-761d5c05741c)
ProductEcostruxure Power Monitoring Expert (2ad3cf64-c32a-5bf4-90f3-479aac2ac155)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2020-7547 vulnerable 2026-06-08 05:27:13.519138 Details available
A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level.
Published: 2020-12-01T14:44:52.000Z
Updated: 2024-08-04T09:33:19.887Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-7546 vulnerable 2026-06-08 05:27:13.518172 Details available
A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage.
Published: 2020-12-01T14:44:31.000Z
Updated: 2024-08-04T09:33:19.932Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2020-7545 vulnerable 2026-06-08 05:27:13.514029 Details available
A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage.
Published: 2020-12-01T14:44:10.000Z
Updated: 2024-08-04T09:33:19.761Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2018-7797 vulnerable 2026-06-08 05:12:04.268033 Details available
A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3 (formerly Power Manager), EcoStruxure Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure Power Monitoring Expert (PME) v9.0, EcoStruxure Energy Expert v2.0, and EcoStruxure Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module which could cause a phishing attack when redirected to a malicious site.
Published: 2018-12-17T22:00:00.000Z
Updated: 2024-08-05T06:37:59.199Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.