Bi Connector Odbc Driver
Approved changes feed: RSS · Atom
cpe:2.3:a:mongodb:bi_connector_odbc_driver:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Mongodb (1aa156a6-63a9-5032-baaf-10197d408a1e) |
|---|---|
| Product | Bi Connector Odbc Driver (52eb9e3e-5ad3-5ea3-81c3-d42ee9102316) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
pkg:github/mongodb/mongo-bi-connector-odbc-driver |
purl2cpe | 2026-09-09 08:33:48.377255 |
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2026-19004 |
vulnerable | 2026-09-16 04:34:15.710712 |
MongoDB BI Connector ODBC Driver Memory-Safety Issue When Handling Stored Procedure Output Parameters
HIGH (8.1)
An application using the MongoDB BI Connector ODBC Driver may experience a memory-safety issue when processing output parameters from a stored procedure. Triggering this issue requires connecting to an untrusted or impersonated database server that returns crafted metadata. This may result in process termination, disclosure of process memory, or, under certain conditions, arbitrary code execution.
Published: 2026-08-12T20:33:13.882Z
Updated: 2026-08-13T14:09:20.563Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2026-19001 |
vulnerable | 2026-09-16 04:34:15.523994 |
MongoDB BI Connector ODBC driver may write outside an allocated buffer when handling oversized catalog object names
CRITICAL (9.8)
The MongoDB BI Connector ODBC Driver may write outside the bounds of a fixed-size buffer when an application supplies an unusually long catalog, schema, or object name to a metadata retrieval function. This may result in memory corruption within the calling application's process, leading to abnormal termination and, under certain conditions, the potential for arbitrary code execution.
Published: 2026-08-12T20:27:02.913Z
Updated: 2026-08-13T12:55:40.150Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2026-19003 |
vulnerable | 2026-09-16 04:34:15.400457 |
MongoDB BI Connector ODBC driver may write outside an allocated buffer when the setup dialog opens a data source with oversized path settings
HIGH (7.8)
A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.
Published: 2026-08-12T21:04:19.140Z
Updated: 2026-08-13T13:44:16.892Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2026-19002 |
vulnerable | 2026-09-16 04:34:15.322985 |
Crafted database metadata may cause memory corruption in MongoDB BI Connector ODBC Driver
HIGH (8.1)
A missing bounds check when parsing stored procedure parameter metadata in the MongoDB BI Connector ODBC Driver can result in an out-of-bounds write in the client application process. Triggering this issue requires control over the server the driver connects to, or the ability to respond in its place, in order to return malformed metadata. The resulting memory corruption may cause the client application to terminate abnormally or, under certain conditions, execute unintended code.
Published: 2026-08-12T20:24:35.156Z
Updated: 2026-08-13T12:55:07.693Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2026-18888 |
vulnerable | 2026-09-16 04:34:01.866750 |
MongoDB BI Connector ODBC driver may write outside an allocated buffer when retrieving large floating point values as character data
MEDIUM (6.5)
The MongoDB BI Connector ODBC Driver converts floating point column values into text without checking that the result fits within the destination buffer. When an application reads a sufficiently large floating point value as text, the driver may write beyond the end of that buffer and corrupt adjacent memory. A user who can store data in a collection read through the BI Connector could use this to crash the application performing the read.
Published: 2026-08-12T20:29:33.618Z
Updated: 2026-08-13T14:14:30.650Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-12100 |
vulnerable | 2026-06-08 07:04:29.685688 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.