Approved changes feed: RSS · Atom

cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*

part: o version: * update: *

VendorEdimax (b21209bc-38b2-5a9c-baa2-25a5068c39e9)
ProductBr 6208Ac Firmware (60d870fb-654a-55a9-8f04-940ddc802786)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2026-7685 vulnerable 2026-06-08 08:08:57.566489 Edimax BR-6208AC setWAN buffer overflow
HIGH (8.8)
A vulnerability was detected in Edimax BR-6208AC up to 1.02. Affected is an unknown function of the file /goform/setWAN. Performing a manipulation of the argument pptpDfGateway  results in buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Published: 2026-05-03T07:00:12.291Z
Updated: 2026-05-04T14:52:55.937Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-7682 vulnerable 2026-06-08 08:08:57.564084 Edimax BR-6208AC L2TP Mode setWAN command injection
MEDIUM (6.3)
A security flaw has been discovered in Edimax BR-6208AC 1.02. The impacted element is the function setWAN of the file /goform/setWAN of the component L2TP Mode. The manipulation of the argument L2TPUserName results in command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Published: 2026-05-03T06:15:09.912Z
Updated: 2026-05-05T17:46:44.840Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-1972 vulnerable 2026-06-08 07:49:09.933759 Edimax BR-6208AC auth_check_userpass2 default credentials
MEDIUM (5.3)
A vulnerability was found in Edimax BR-6208AC 2_1.02. The affected element is the function auth_check_userpass2. Performing a manipulation of the argument Username/Password results in use of default credentials. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer.
Published: 2026-02-06T01:02:06.557Z
Updated: 2026-02-23T09:19:31.030Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-15258 vulnerable 2026-06-08 07:06:35.950874 Edimax BR-6208AC Web-based Configuration formALGSetup redirect
LOW (3.5)
A weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of the component Web-based Configuration Interface. This manipulation of the argument wlan-url causes open redirect. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.
Published: 2025-12-30T17:32:05.860Z
Updated: 2026-02-24T06:18:29.080Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-15257 vulnerable 2026-06-08 07:06:35.950299 Edimax BR-6208AC Web-based Configuration formRoute command injection
HIGH (7.3)
A security flaw has been discovered in Edimax BR-6208AC 1.02/1.03. Affected by this vulnerability is the function formRoute of the file /gogorm/formRoute of the component Web-based Configuration Interface. The manipulation of the argument strIp/strMask/strGateway results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.
Published: 2025-12-30T17:02:06.973Z
Updated: 2026-02-24T06:18:16.458Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-15256 vulnerable 2026-06-08 07:06:35.948059 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-14910 vulnerable 2026-06-08 07:06:35.346902 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data

Contribute