Meac300 Fnade4 Firmware
Approved changes feed: RSS · Atom
cpe:2.3:o:endress:meac300-fnade4_firmware:*:*:*:*:*:*:*:*
part: o version: * update: *
| Vendor | Endress (3c08e0d0-0a0b-59fa-8b29-bcefa13da872) |
|---|---|
| Product | Meac300 Fnade4 Firmware (1e8bff51-934b-5c90-a68c-5f9b1252feab) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2025-27461 |
vulnerable | 2026-06-03 15:00:12.520028 |
CVE-2025-27461
HIGH (7.6)
During startup, the device automatically logs in the EPC2 Windows user without requesting a password.
Published: 2025-07-03T11:34:52.786Z
Updated: 2025-07-03T13:15:27.472Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27460 |
vulnerable | 2026-06-03 15:00:12.519469 |
CVE-2025-27460
HIGH (7.6)
The hard drives of the device are not encrypted using a full volume encryption feature such as BitLocker. This allows an attacker with physical access to the device to use an alternative operating system to interact with the hard drives, completely circumventing the Windows login. The attacker can read from and write to all files on the hard drives.
Published: 2025-07-03T11:34:21.220Z
Updated: 2025-07-03T13:15:32.379Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27459 |
vulnerable | 2026-06-03 15:00:12.519021 |
CVE-2025-27459
MEDIUM (4.4)
The VNC application stores its passwords encrypted within the registry but uses DES for encryption. As DES is broken, the original passwords can be recovered.
Published: 2025-07-03T11:33:53.899Z
Updated: 2025-07-03T13:15:37.506Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27458 |
vulnerable | 2026-06-03 15:00:12.518353 |
CVE-2025-27458
MEDIUM (6.5)
The VNC authentication mechanism bases on a challenge-response system where both server and client use the same password for encryption. The challenge is sent from the server to the client, is encrypted by the client and sent back. The server does the same encryption locally and if the responses match it is prooven that the client knows the correct password. Since all VNC communication is unencrypted, an attacker can obtain the challenge and response and try to derive the password from this information.
Published: 2025-07-03T11:33:30.605Z
Updated: 2025-07-03T13:15:43.013Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27457 |
vulnerable | 2026-06-03 15:00:12.517677 |
CVE-2025-27457
MEDIUM (6.5)
All communication between the VNC server and client(s) is unencrypted. This allows an attacker to intercept the traffic and obtain sensitive data.
Published: 2025-07-03T11:32:59.576Z
Updated: 2025-07-03T13:15:48.078Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27456 |
vulnerable | 2026-06-03 15:00:12.505978 |
CVE-2025-27456
HIGH (7.5)
The SMB server's login mechanism does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
Published: 2025-07-03T11:32:21.466Z
Updated: 2025-07-03T13:15:53.469Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27455 |
vulnerable | 2026-06-03 15:00:12.505507 |
CVE-2025-27455
MEDIUM (4.3)
The web application is vulnerable to clickjacking attacks. The site can be embedded into another frame, allowing an attacker to trick a user into clicking on something different from what the user perceives, thus potentially revealing confidential information or allowing others to take control of their computer while clicking on seemingly innocuous objects.
Published: 2025-07-03T11:30:49.265Z
Updated: 2025-07-03T13:15:59.115Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27454 |
vulnerable | 2026-06-03 15:00:12.505026 |
CVE-2025-27454
MEDIUM (4.3)
The application is vulnerable to cross-site request forgery. An attacker can trick a valid, logged in user into submitting a web request that they did not intend. The request uses the victim's browser's saved authorization to execute the request.
Published: 2025-07-03T11:30:19.944Z
Updated: 2025-07-03T13:16:05.545Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27453 |
vulnerable | 2026-06-03 15:00:12.504448 |
CVE-2025-27453
MEDIUM (5.3)
The HttpOnly flag is set to false on the PHPSESSION cookie. Therefore, the cookie can be accessed by other sources such as JavaScript.
Published: 2025-07-03T11:29:48.216Z
Updated: 2025-07-03T13:16:11.391Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27452 |
vulnerable | 2026-06-03 15:00:12.503919 |
CVE-2025-27452
MEDIUM (5.3)
The configuration of the Apache httpd webserver which serves the MEAC300-FNADE4 web application, is partly insecure. There are modules activated that are not required for the operation of the FNADE4 web application. The functionality of the some modules
pose a risk to the webserver which enable dircetory listing.
Published: 2025-07-03T11:29:04.003Z
Updated: 2025-07-03T13:16:16.586Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27451 |
vulnerable | 2026-06-03 15:00:12.503429 |
CVE-2025-27451
MEDIUM (5.3)
For failed login attempts, the application returns different error messages depending on whether the login failed due to an incorrect password or a non-existing username. This allows an attacker to guess usernames until they find an existing one.
Published: 2025-07-03T11:27:35.372Z
Updated: 2025-07-03T13:16:21.696Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27450 |
vulnerable | 2026-06-03 15:00:12.502831 |
CVE-2025-27450
MEDIUM (6.5)
The Secure attribute is missing on multiple cookies provided by the MEAC300-FNADE4. An attacker can trick a user to establish an unencrypted HTTP connection to the server and intercept the request containing the PHPSESSID cookie.
Published: 2025-07-03T11:26:33.462Z
Updated: 2025-07-03T13:16:27.030Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27449 |
vulnerable | 2026-06-03 15:00:12.502256 |
CVE-2025-27449
HIGH (7.5)
The MEAC300-FNADE4 does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
Published: 2025-07-03T11:25:45.104Z
Updated: 2025-07-03T13:16:31.757Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27448 |
vulnerable | 2026-06-03 15:00:12.501704 |
CVE-2025-27448
MEDIUM (6.8)
The web application is susceptible to cross-site-scripting attacks. An attacker who can create new dashboards can inject JavaScript code into the dashboard name which will be executed when the website is loaded.
Published: 2025-07-03T11:24:00.307Z
Updated: 2025-07-03T13:16:36.782Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-27447 |
vulnerable | 2026-06-03 15:00:12.500436 |
CVE-2025-27447
HIGH (7.4)
The web application is susceptible to cross-site-scripting attacks. An attacker can create a prepared URL, which injects JavaScript code into the website. The code is executed in the victim’s browser when an authenticated administrator clicks the link.
Published: 2025-07-03T11:23:20.043Z
Updated: 2025-07-03T13:16:41.793Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-1711 |
vulnerable | 2026-06-03 14:59:06.207520 |
CVE-2025-1711
MEDIUM (4.3)
Multiple services of the DUT as well as different scopes of the same service reuse the same credentials.
Published: 2025-07-03T11:22:09.710Z
Updated: 2025-07-03T13:16:47.136Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-1710 |
vulnerable | 2026-06-03 14:59:06.207013 |
CVE-2025-1710
HIGH (7.5)
The maxView Storage Manager does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
Published: 2025-07-03T11:21:18.058Z
Updated: 2025-07-03T13:16:53.110Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-1709 |
vulnerable | 2026-06-03 14:59:06.206381 |
CVE-2025-1709
MEDIUM (6.5)
Several credentials for the local PostgreSQL database are stored in plain text (partially base64 encoded).
Published: 2025-07-03T11:20:20.793Z
Updated: 2025-07-03T13:17:00.475Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-1708 |
vulnerable | 2026-06-03 14:59:06.204801 |
CVE-2025-1708
HIGH (8.6)
The application is vulnerable to SQL injection attacks. An attacker is able to dump the PostgreSQL database and read its content.
Published: 2025-07-03T11:18:22.134Z
Updated: 2025-07-03T13:17:20.348Z |
Imported from gcve-enriched-dumps CVE data |
Contribute