Melsec Iq F Series Fx5 Enet/Ip Ethernet Module Fx5 Enet/Ip
Approved changes feed: RSS · Atom
cpe:2.3:a:mitsubishi_electric_corporation:melsec_iq-f_series_fx5-enet/ip_ethernet_module_fx5-enet/ip:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Mitsubishi Electric Corporation (d664dc32-cd69-5fcd-bcda-db4283d1f666) |
|---|---|
| Product | Melsec Iq F Series Fx5 Enet/Ip Ethernet Module Fx5 Enet/Ip (a741c474-965a-5bab-b109-5c35143dc415) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2026-1876 |
vulnerable | 2026-06-08 07:49:09.787618 |
Denial-of-Service (DoS) vulnerability in Ethernet function of MELSEC iQ-F Series Ethernet module
Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP all versions allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery.
Published: 2026-03-03T07:03:13.328Z
Updated: 2026-03-04T08:25:07.248Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2026-1874 |
vulnerable | 2026-06-08 07:49:09.781341 |
Denial-of-Service (DoS) vulnerability in Ethernet function of MELSEC iQ-F Series EtherNet/IP module and Ethernet module
Always-Incorrect Control Flow Implementation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP versions 1.106 and prior and Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP versions 1.000 and prior allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery.
Published: 2026-03-03T06:46:21.526Z
Updated: 2026-04-24T07:24:38.061Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-3511 |
vulnerable | 2026-06-08 07:23:09.214912 |
Details available
HIGH (7.5)
Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, and MELSEC iQ-F Series FX5-ENET/IP Ethernet Module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.
Published: 2025-04-25T05:14:43.758Z
Updated: 2026-04-24T07:13:32.562Z |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.