Diris Digiware M 70 Firmware
Approved changes feed: RSS · Atom
cpe:2.3:o:socomec:diris_digiware_m-70_firmware:1.6.9:*:*:*:*:*:*:*
part: o version: 1.6.9 update: *
| Vendor | Socomec (b2889dfa-9d82-58cf-9a0a-02ccbb62a6ab) |
|---|---|
| Product | Diris Digiware M 70 Firmware (6f5256f8-7d22-5405-8db1-abd68b5d4d81) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2025-54849 |
vulnerable | 2026-06-08 07:33:13.477029 |
Details available
HIGH (7.5)
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a single Modbus TCP message to port 502 using the Write Single Register function code (6) to write the value 1 to register 4352. This action changes the Modbus address to 15. After this message is sent, the device will be in a denial-of-service state.
Published: 2025-12-01T15:25:13.025Z
Updated: 2025-12-01T20:16:27.906Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-54848 |
vulnerable | 2026-06-08 07:33:13.475802 |
Details available
HIGH (7.5)
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a sequence of Modbus TCP messages to port 502 using the Write Single Register function code (6). The attack sequence begins with a message to register 58112 with a value of 1000, indicating that a configuration change will follow. Next, a message is sent to register 29440 with a value corresponding to the new Modbus address to be configured. Finally, a message to register 57856 with a value of 161 commits the configuration change. After this configuration change, the device will be in a denial-of-service state.