Approved changes feed: RSS · Atom

cpe:2.3:a:automationdirect:click_plus_c2-x_cpu_firmware:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorAutomationdirect (5dd60aaf-eea3-5732-9a9c-5b671c0ed914)
ProductClick Plus C2 X Cpu Firmware (5ed5aece-e460-55c2-b3ea-de5dd567ad11)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2025-59484 vulnerable 2026-06-08 07:35:22.056227 AutomationDirect CLICK PLUS Use of a Broken or Risky Cryptographic Algorithm
HIGH (8.3)
The use of a broken or risky cryptographic algorithm was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software uses an insecure implementation of the RSA encryption algorithm.
Published: 2025-09-23T22:08:40.744Z
Updated: 2025-09-24T14:08:07.973Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-58473 vulnerable 2026-06-08 07:35:18.399595 AutomationDirect CLICK PLUS Improper Resource Shutdown or Release
MEDIUM (5.9)
An improper resource shutdown or release vulnerability has been identified in the Click Plus C2-03CPU-2 device running firmware version 3.60. The vulnerability allows an unauthenticated attacker to perform a denial-of-service attack by exhausting all available device sessions of the Click Programming Software.
Published: 2025-09-23T22:21:06.164Z
Updated: 2025-09-24T14:07:48.727Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-58069 vulnerable 2026-06-08 07:35:17.034147 AutomationDirect CLICK PLUS Use of Hard-coded Cryptographic Key
MEDIUM (5.3)
The use of a hard-coded cryptographic key was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software contains a hard-coded AES key used to protect the initial messages of a new KOPS session.
Published: 2025-09-23T22:04:58.449Z
Updated: 2025-09-24T14:08:24.132Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-57882 vulnerable 2026-06-08 07:33:16.303629 AutomationDirect CLICK PLUS Improper Resource Shutdown or Release
MEDIUM (5.9)
An improper resource shutdown or release vulnerability has been identified in the Click Plus C2-03CPU-2 device running firmware version 3.60. The vulnerability allows an unauthenticated attacker to perform a denial-of-service attack by exhausting all available device sessions in the Remote PLC application.
Published: 2025-09-23T22:27:02.078Z
Updated: 2025-09-24T14:05:58.599Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-55069 vulnerable 2026-06-08 07:33:14.028562 AutomationDirect CLICK PLUS Predictable Seed in Pseudo-Random Number Generator
HIGH (8.3)
A predictable seed in pseudo-random number generator vulnerability has been discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software implements a predictable seed for its pseudo-random number generator, which compromises the security of the generated private keys.
Published: 2025-09-23T22:15:46.833Z
Updated: 2025-09-24T14:07:59.115Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-55038 vulnerable 2026-06-08 07:33:14.001375 db.gcve.eu details were skipped to keep the page responsive. Imported from gcve-enriched-dumps CVE data