Approved changes feed: RSS · Atom
cpe:2.3:a:vivotek:ip7137:*:*:*:*:*:*:*:*
part: a version: * update: *
| Vendor | Vivotek (f3d58ac8-0e4b-5832-9edd-ecd09cb2aa5c) |
|---|---|
| Product | Ip7137 (8737dab5-7163-5d42-96c9-4ceb9c99af84) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from gcve-enriched-dumps CVE data |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2025-66052 |
vulnerable | 2026-06-08 07:39:21.171292 |
Command injection in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,
The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Published: 2026-01-09T11:54:16.626Z
Updated: 2026-01-09T12:51:10.558Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-66051 |
vulnerable | 2026-06-08 07:39:21.170819 |
Path traversal in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default.
The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Published: 2026-01-09T11:54:09.170Z
Updated: 2026-01-09T14:07:13.457Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-66050 |
vulnerable | 2026-06-08 07:39:21.170162 |
No password set for administrative account in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.
The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Published: 2026-01-09T11:53:45.338Z
Updated: 2026-01-09T14:08:08.233Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2025-66049 |
vulnerable | 2026-06-08 07:39:21.162995 |
Unprotected RTSP stream in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.
The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Published: 2026-01-09T11:53:41.060Z
Updated: 2026-01-09T16:22:19.535Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.