cpe:2.3:h:vivotek:ip7137:-:*:*:*:*:*:*:*

part: h version: - update: *

VendorVivotek (f3d58ac8-0e4b-5832-9edd-ecd09cb2aa5c)
ProductIp7137 (8737dab5-7163-5d42-96c9-4ceb9c99af84)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2025-66052 not_vulnerable 2026-06-08 07:39:21.171614 Command injection in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,  The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Published: 2026-01-09T11:54:16.626Z
Updated: 2026-01-09T12:51:10.558Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-66051 not_vulnerable 2026-06-08 07:39:21.170874 Path traversal in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Published: 2026-01-09T11:54:09.170Z
Updated: 2026-01-09T14:07:13.457Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-66050 not_vulnerable 2026-06-08 07:39:21.170328 No password set for administrative account in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Published: 2026-01-09T11:53:45.338Z
Updated: 2026-01-09T14:08:08.233Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2025-66049 not_vulnerable 2026-06-08 07:39:21.169710 Unprotected RTSP stream in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.  The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Published: 2026-01-09T11:53:41.060Z
Updated: 2026-01-09T16:22:19.535Z
Reference links
Imported from gcve-enriched-dumps CVE data