Approved changes feed: RSS · Atom

cpe:2.3:a:mobiliti:e-mobi.hu:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorMobiliti (06b0c999-d827-581c-ac16-369cf763cecd)
ProductE Mobi.Hu (ac34eff6-b862-5eed-9d0f-e99f0e6e88d8)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*

Notes

Imported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2026-27777 vulnerable 2026-06-08 07:55:13.799233 Mobiliti e-mobi.hu Insufficiently Protected Credentials
MEDIUM (6.5)
Charging station authentication identifiers are publicly accessible via web-based mapping platforms.
Published: 2026-03-06T15:09:22.057Z
Updated: 2026-03-12T15:54:09.223Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-27764 vulnerable 2026-06-08 07:55:13.756040 Mobiliti e-mobi.hu Insufficient Session Expiration
HIGH (7.3)
The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.
Published: 2026-03-06T15:07:32.848Z
Updated: 2026-03-10T17:59:28.839Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-26051 vulnerable 2026-06-08 07:53:20.756404 Mobiliti e-mobi.hu Missing Authentication for Critical Function
CRITICAL (9.4)
WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend.
Published: 2026-03-06T15:03:03.668Z
Updated: 2026-03-09T15:21:58.096Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-20882 vulnerable 2026-06-08 07:49:13.382755 Mobiliti e-mobi.hu Improper Restriction of Excessive Authentication Attempts
HIGH (7.5)
The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access.
Published: 2026-03-06T15:05:42.589Z
Updated: 2026-03-10T17:59:37.339Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.

Inspect record JSON

Open JSON directly

Open this panel to browse, search, copy or download the JSON record.