Approved changes feed: RSS · Atom

cpe:2.3:a:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_(incl._siplus_variants)_v2_cpus:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorSiemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f)
ProductSimatic Et 200Sp Open Controller Cpu 1515Sp Pc2 (Incl. Siplus Variants) V2 Cpus (4fe3af60-461b-5f4d-8b06-74f23c621b60)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2026-25789 vulnerable 2026-06-08 07:53:20.460372 Details available
HIGH (7.1)
Affected devices do not properly validate and sanitize filenames on the Firmware Update page. This could allow a remote attacker to social engineer the user into selecting the modified firmware file to be uploaded. This would result in malitcious JavaScript execution in the context of the authenticated user's session without requiring the file to be uploaded, potentially leading to session hijacking or credential theft.
Published: 2026-05-12T08:21:10.076Z
Updated: 2026-07-14T09:19:16.119Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-25787 vulnerable 2026-06-08 07:53:20.452249 Details available
CRITICAL (9.1)
Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a benign user with appropriate rights accesses the "Motion Control Diagnostics" parameters page, the malicious code would be executed in the scope of their web session.
Published: 2026-05-12T08:21:06.426Z
Updated: 2026-07-14T09:19:14.087Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-25786 vulnerable 2026-06-08 07:53:20.366770 Details available
CRITICAL (9.1)
Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a benign user with appropriate rights accesses the "communication" parameters page, the malicious code would be executed in the scope of their web session.
Published: 2026-05-12T08:20:58.605Z
Updated: 2026-07-14T09:19:12.039Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.