Approved changes feed: RSS · Atom

cpe:2.3:a:picotronica:e-clinic_healthcare_system_echs:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorPicotronica (93a76d54-86bb-5c5f-bc4b-924a3bbd2254)
ProductE Clinic Healthcare System Echs (09f1844f-ca05-5444-8f0c-fab9943110eb)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*

Notes

Imported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2026-8033 vulnerable 2026-06-08 08:08:57.966508 PicoTronica e-Clinic Healthcare System ECHS Response Header v2 information disclosure
MEDIUM (5.3)
A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. Upgrading to version 5.7.1 mitigates this issue. It is suggested to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
Published: 2026-05-06T19:30:16.794Z
Updated: 2026-05-07T14:59:40.518Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-8032 vulnerable 2026-06-08 08:08:57.965987 PicoTronica e-Clinic Healthcare System ECHS echs.js hard-coded credentials
HIGH (7.3)
A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMIN_KEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has been published and may be used. Upgrading to version 5.7.1 is sufficient to resolve this issue. The affected component should be upgraded. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
Published: 2026-05-06T19:00:20.735Z
Updated: 2026-05-07T13:55:16.912Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-8031 vulnerable 2026-06-08 08:08:57.965602 PicoTronica e-Clinic Healthcare System ECHS API Endpoint patient-records missing authentication
MEDIUM (5.3)
A vulnerability was detected in PicoTronica e-Clinic Healthcare System ECHS 5.7. The affected element is an unknown function of the file /cdemos/echs/api/v2/patient-records of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The exploit is now public and may be used. Upgrading to version 5.7.1 is sufficient to fix this issue. You should upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
Published: 2026-05-06T18:00:18.864Z
Updated: 2026-05-06T18:37:26.894Z
Reference links
Imported from gcve-enriched-dumps CVE data