Approved changes feed: RSS · Atom

cpe:2.3:a:loytec:l-vis:*:*:*:*:*:*:*:*

part: a version: * update: *

VendorLoytec (6190caa2-852a-5dba-b6c8-40e7b31c6b3d)
ProductL Vis (caca1936-d6b9-547a-a9f6-144c18708f68)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from gcve-enriched-dumps CVE data

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2026-55732 vulnerable 2026-07-29 01:00:28.597808 Loytec LINX firmware: Out-of-bounds Read in BACnet packet parsing (bacdt_datetime_to_tod)
Out-of-bounds Read (CWE-125) in BACnet packet parsing (`bacdt_datetime_to_tod`) in Loytec LIP-ME201C, L-INX, L-GATE, L-ROC, L-IOB, L-DALI, L-VIS and L-PAD through 8.4.18 on LINX-A64 allows an unauthenticated remote attacker to crash `linx_a64.exe` and ultimately reboot the device via a malformed BACnet TimeSynchronization or UTC-TimeSynchronization packet with an invalid month value. The same vulnerability affects multiple other Loytec products.
Published: 2026-07-24T14:00:48.771Z
Updated: 2026-07-24T14:53:49.184Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-55731 vulnerable 2026-07-29 01:00:28.597146 Loytec LINX firmware: Unchecked input for loop condition in the SNMP agent
Unchecked input for loop condition (CWE-606) in the SNMP agent in Loytec LIP-ME201C, L-INX, L-GATE, L-ROC, L-IOB, L-DALI, L-VIS and L-PAD through 8.4.16 on LINX-A64 allows an unauthenticated remote attacker to cause persistent denial of service (CPU exhaustion) via a crafted SNMP GETNEXT request with a large OID component.
Published: 2026-07-24T14:00:30.497Z
Updated: 2026-07-24T14:54:34.007Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-55728 vulnerable 2026-07-29 01:00:28.591377 Loytec LINX firmware: Stack-based Buffer Overflow in cmd_ipaddr_conflict
Stack-based Buffer Overflow (CWE-121) in `/usr/bin/ltsudo` `cmd_ipaddr_conflict` in Loytec LIP-ME201C, L-INX, L-GATE, L-ROC, L-IOB, L-DALI, L-VIS and L-PAD through 8.4.16 on LINX-A64 allows a `superadmin`-group attacker to trigger a SUID-root process abort or potentially elevate privileges via an overly long interface-name argument.
Published: 2026-07-24T13:58:35.474Z
Updated: 2026-07-24T14:56:40.020Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2026-12504 vulnerable 2026-07-29 00:23:32.390855 Loytec LINX firmware: Improper Authentication in PAM configuration
Improper Authentication (CWE-287) in the PAM configuration in Loytec LIP-ME201C, L-INX, L-GATE, L-ROC, L-IOB, L-DALI, L-VIS and L-PAD through 8.4.16 on LINX-A64 allows a local attacker to authenticate as a uid=0 account without a password and obtain a root shell via an `/etc/passwd` entry with an empty password field.
Published: 2026-07-24T13:58:16.232Z
Updated: 2026-07-24T14:57:20.563Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.