Approved changes feed: RSS · Atom

cpe:2.3:o:crestron:am-101_firmware:2.7.0.2:*:*:*:*:*:*:*

part: o version: 2.7.0.2 update: *

VendorCrestron (c3f889c7-b88c-556e-9a5e-f70525099cf1)
ProductAm 101 Firmware (f1e1b725-8257-5d34-b53b-7fc10c41d5d1)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2019-3939 vulnerable 2026-06-03 14:40:27.906857 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device.
Published: 2019-04-30T20:40:18.000Z
Updated: 2024-08-04T19:26:27.803Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3938 vulnerable 2026-06-03 14:40:27.906519 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords.
Published: 2019-04-30T20:39:24.000Z
Updated: 2024-08-04T19:26:27.938Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3937 vulnerable 2026-06-03 14:40:27.906146 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data.
Published: 2019-04-30T20:38:24.000Z
Updated: 2024-08-04T19:26:27.781Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3936 vulnerable 2026-06-03 14:40:27.905785 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 is vulnerable to denial of service via a crafted request to TCP port 389. The request will force the slideshow to transition into a "stopped" state. A remote, unauthenticated attacker can use this vulnerability to stop an active slideshow.
Published: 2019-04-30T20:35:48.000Z
Updated: 2024-08-04T19:26:27.921Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3935 vulnerable 2026-06-03 14:40:27.905424 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi. A remote, unauthenticated attacker can use this vulnerability to start, stop, and disconnect active slideshows.
Published: 2019-04-30T20:34:51.000Z
Updated: 2024-08-04T19:26:27.786Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3934 vulnerable 2026-06-03 14:40:27.905057 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi. A remote, unauthenticated attacker can use this vulnerability to download the current slide image without knowing the access code.
Published: 2019-04-30T20:34:03.000Z
Updated: 2024-08-04T19:26:27.453Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3933 vulnerable 2026-06-03 14:40:27.904697 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code.
Published: 2019-04-30T20:30:50.000Z
Updated: 2024-08-04T19:26:27.523Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3932 vulnerable 2026-06-03 14:40:27.904325 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge.
Published: 2019-04-30T20:30:02.000Z
Updated: 2024-08-04T19:26:27.558Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3931 vulnerable 2026-06-03 14:40:27.903858 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi. A remote, authenticated attacker can use this vulnerability to upload files to the device and ultimately execute code as root.
Published: 2019-04-30T20:28:44.000Z
Updated: 2024-08-04T19:26:27.568Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3930 vulnerable 2026-06-03 14:40:27.903123 Details available
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so's PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint.
Published: 2019-04-30T20:25:56.000Z
Updated: 2024-08-04T19:26:27.743Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3929 vulnerable 2026-06-03 14:40:27.891110 Details available
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Published: 2019-04-30T20:21:09.000Z
Updated: 2025-10-21T23:45:38.287Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3928 vulnerable 2026-06-03 14:40:27.887775 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allow any user to obtain the presentation passcode via the iso.3.6.1.4.1.3212.100.3.2.7.4 OIDs. A remote, unauthenticated attacker can use this vulnerability to access a restricted presentation or to become the presenter.
Published: 2019-04-30T20:18:34.000Z
Updated: 2024-08-04T19:26:27.641Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3927 vulnerable 2026-06-03 14:40:27.887414 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 anyone can change the administrator and moderator passwords via the iso.3.6.1.4.1.3212.100.3.2.8.1 and iso.3.6.1.4.1.3212.100.3.2.8.2 OIDs. A remote, unauthenticated attacker can use this vulnerability to change the admin or moderator user's password and gain access to restricted areas on the HTTP interface.
Published: 2019-04-30T20:15:32.000Z
Updated: 2024-08-04T19:26:27.355Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3926 vulnerable 2026-06-03 14:40:27.887014 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.14.1. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Published: 2019-04-30T20:12:46.000Z
Updated: 2024-08-04T19:26:27.268Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-3925 vulnerable 2026-06-03 14:40:27.886063 Details available
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.9.3. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Published: 2019-04-30T20:09:51.000Z
Updated: 2024-08-04T19:26:26.699Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.