Approved changes feed: RSS · Atom

cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*

part: h version: - update: *

VendorSiemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f)
ProductSimatic Winac Rtx (51ebe918-0b8c-59d1-8c59-e49151663ec5)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2022-25622 not_vulnerable 2026-06-08 05:41:46.171323 Details available
MEDIUM (5.3)
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
Published: 2022-04-12T00:00:00.000Z
Updated: 2025-04-21T13:54:36.799Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-6568 not_vulnerable 2026-06-08 05:14:12.152845 Details available
HIGH (7.5)
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
Published: 2019-04-17T13:40:24.000Z
Updated: 2026-06-03T13:29:34.953Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-2681 not_vulnerable 2026-06-08 05:09:25.295468 Details available
MEDIUM (6.5)
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
Published: 2017-05-11T10:00:00.000Z
Updated: 2024-09-10T09:33:20.658Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2017-2680 not_vulnerable 2026-06-08 05:09:25.200295 Details available
MEDIUM (6.5)
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Published: 2017-05-11T01:00:00.000Z
Updated: 2024-09-10T09:33:18.492Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.