cpe:2.3:h:bosch:smart_home_controller:-:*:*:*:*:*:*:*

part: h version: - update: *

VendorBosch (fd8ddba2-7d59-56e9-89d8-6fcadc94214e)
ProductSmart Home Controller (c539822b-f8e0-5157-a3ba-fb160f4b2b9f)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2019-11896 not_vulnerable 2026-06-08 05:12:38.280010 Incorrect pviilege assignment in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC)
MEDIUM (5.5)
A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction.
Published: 2019-05-29T20:11:00.829Z
Updated: 2024-09-16T19:24:49.342Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-11894 not_vulnerable 2026-06-08 05:12:38.277403 Improper access control in the backup mechanism of the Bosch Smart Home Controller (SHC)
MEDIUM (5.7)
A potential improper access control vulnerability exists in the backup mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in unauthorized download of a backup. In order to exploit the vulnerability, the adversary needs to download the backup directly after a backup triggered by a legitimate user has been completed.
Published: 2019-05-29T20:03:48.103Z
Updated: 2024-09-17T00:46:00.989Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-11893 not_vulnerable 2026-06-08 05:12:38.277044 Incorrect privilege assignment in the app permission update API of the Bosch Smart Home Controller (SHC)
MEDIUM (5.5)
A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app with restricted permissions, which required user interaction.
Published: 2019-05-29T19:58:04.150Z
Updated: 2024-09-16T22:46:47.017Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-11892 not_vulnerable 2026-06-08 05:12:38.276667 Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)
HIGH (7.5)
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction.
Published: 2019-05-29T19:55:13.289Z
Updated: 2024-09-16T17:42:58.052Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2019-11891 not_vulnerable 2026-06-08 05:12:38.276191 Incorrect privilege assignment in the app pairing mechanism of the Bosch Smart Home Controller (SHC)
HIGH (8)
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.
Published: 2019-05-29T19:40:01.253Z
Updated: 2024-09-16T18:13:51.172Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.