Philips Patient Information Center IX C.03
Approved changes feed: RSS · Atom
cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:*
part: a version: c.03 update: *
| Vendor | Philips (b8a9f1cf-d82f-5e30-aade-8a8018bb7a6f) |
|---|---|
| Product | Patient Information Center Ix (52758c44-d400-5bf9-bc57-a978a41dc804) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2021-43552 |
vulnerable | 2026-06-08 05:36:43.541833 |
Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of Hard-coded Cryptographic Key
MEDIUM (6.1)
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03.
Published: 2021-12-27T18:48:22.163Z
Updated: 2024-09-17T00:16:34.580Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-43550 |
vulnerable | 2026-06-08 05:36:43.536431 |
Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of a Broken or Risky Cryptographic Algorithm
MEDIUM (5.9)
The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0.
Published: 2021-12-27T18:48:23.613Z
Updated: 2024-09-16T19:00:27.450Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-43548 |
vulnerable | 2026-06-08 05:36:43.533527 |
Philips Patient Information Center iX (PIC iX) and Efficia CM Series Improper Input Validation
MEDIUM (6.5)
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
Published: 2021-12-27T18:48:22.881Z
Updated: 2024-09-16T16:38:33.233Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-16228 |
vulnerable | 2026-06-08 05:19:27.756568 |
Philips Patient Monitoring Devices Improper Check for Certificate Revocation
In Patient Information Center iX (PICiX) Versions C.02 and C.03,
PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors
MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and
prior, the software does not check or incorrectly checks the revocation
status of a certificate, which may cause it to use a compromised
certificate.
Published: 2020-09-11T12:58:13.000Z
Updated: 2024-08-04T13:37:54.179Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-16224 |
vulnerable | 2026-06-08 05:19:27.588985 |
Philips Patient Monitoring Devices Improper Handling of Length Parameter Inconsistency
In Patient Information Center iX (PICiX) Versions C.02, C.03, the
software parses a formatted message or structure but does not handle or
incorrectly handles a length field that is inconsistent with the actual
length of the associated data, causing the application on the
surveillance station to restart.
Published: 2020-09-11T13:05:19.000Z
Updated: 2024-08-04T13:37:53.948Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-16222 |
vulnerable | 2026-06-08 05:19:27.588057 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-16220 |
vulnerable | 2026-06-08 05:19:27.587039 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-16218 |
vulnerable | 2026-06-08 05:19:27.582602 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-16216 |
vulnerable | 2026-06-08 05:19:27.563032 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-16214 |
vulnerable | 2026-06-08 05:19:27.559119 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2020-16212 |
vulnerable | 2026-06-08 05:19:27.558246 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |