General ElectricIntelligent Platforms Proficy HMI/SCADA CIMPLICITY 8.2
Approved changes feed: RSS · Atom
cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_cimplicity:8.2:*:*:*:*:*:*:*
part: a version: 8.2 update: *
| Vendor | Ge (889d94a1-c6d7-5857-8fdf-da634b4dfc4f) |
|---|---|
| Product | Intelligent Platforms Proficy Hmi/Scada Cimplicity (c5d6e04f-0fb9-5763-a520-d63d6aa5e4a0) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2014-0751 |
vulnerable | 2026-06-08 05:05:14.170239 |
GE Proficy HMI/SCADA Path Traversal
The CIMPLICITY Web-based access component, CimWebServer, does not check
the location of shell files being loaded into the system. By modifying
the source location, an attacker could send shell code to the
CimWebServer which would deploy the nefarious files as part of any SCADA
project. This could allow the attacker to execute arbitrary code.
Published: 2014-01-25T22:00:00.000Z
Updated: 2025-08-22T22:51:23.718Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2014-0750 |
vulnerable | 2026-06-08 05:05:14.168828 |
GE Proficy HMI/SCADA Path Traversal
Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622.
Published: 2014-01-25T22:00:00.000Z
Updated: 2025-08-22T22:52:23.571Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2013-2823 |
vulnerable | 2026-06-08 05:04:28.058631 |
Details available
The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line.
Published: 2013-11-22T01:00:00.000Z
Updated: 2024-08-06T15:52:19.954Z Reference links
|
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2013-2811 |
vulnerable | 2026-06-08 05:04:28.030425 |
Details available
The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet.
Published: 2013-11-22T01:00:00.000Z
Updated: 2024-08-06T15:52:21.430Z Reference links
|
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2013-2785 |
vulnerable | 2026-06-08 05:04:27.925983 |
Details available
Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted data in packets to TCP port 10212, aka ZDI-CAN-1621 and ZDI-CAN-1624.
Published: 2013-07-31T10:00:00.000Z
Updated: 2024-09-16T22:24:45.426Z |
Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.