Mercedes-benz A 220 4MATIC
Approved changes feed: RSS · Atom
cpe:2.3:h:mercedes-benz:a_220_4matic:-:*:*:*:*:*:*:*
part: h version: - update: *
| Vendor | Mercedes Benz (602afdd2-1ab8-56f6-aa42-d47d3da6f9a1) |
|---|---|
| Product | A 220 4Matic (9ac1ac22-e71b-5420-a6e1-2037c503eab4) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2021-23910 |
not_vulnerable | 2026-06-03 14:43:55.870762 |
Details available
MEDIUM (5.3)
An issue was discovered in HERMES 2.1 in the MBUX Infotainment System on Mercedes-Benz vehicles through 2021. There is an out-of-bounds array access in RemoteDiagnosisApp.
Published: 2021-05-13T18:57:47.000Z
Updated: 2024-08-03T19:14:09.624Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-23909 |
not_vulnerable | 2026-06-03 14:43:55.870164 |
Details available
MEDIUM (6.3)
An issue was discovered in HERMES 2.1 in the MBUX Infotainment System on Mercedes-Benz vehicles through 2021. The SH2 MCU allows remote code execution.
Published: 2021-05-13T18:57:38.000Z
Updated: 2024-08-03T19:14:09.561Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-23908 |
not_vulnerable | 2026-06-03 14:43:55.867398 |
Details available
LOW (2.9)
An issue was discovered in the Headunit NTG6 in the MBUX Infotainment System on Mercedes-Benz vehicles through 2021. A type confusion issue affects MultiSvSetAttributes in the HiQnet Protocol, leading to remote code execution.
Published: 2021-05-13T18:57:21.000Z
Updated: 2024-08-03T19:14:09.466Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-23907 |
not_vulnerable | 2026-06-03 14:43:55.866807 |
Details available
LOW (2.9)
An issue was discovered in the Headunit NTG6 in the MBUX Infotainment System on Mercedes-Benz vehicles through 2021. The count in MultiSvGet, GetAttributes, and MultiSvSet is not checked in the HiQnet Protocol, leading to remote code execution.
Published: 2021-05-13T18:56:51.000Z
Updated: 2024-08-03T19:14:09.387Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-23906 |
not_vulnerable | 2026-06-03 14:43:55.862788 |
Details available
LOW (1.8)
An issue was discovered in the Headunit NTG6 in the MBUX Infotainment System on Mercedes-Benz vehicles through 2021. A Message Length is not checked in the HiQnet Protocol, leading to remote code execution.
Published: 2021-05-13T18:56:32.000Z
Updated: 2024-08-03T19:14:09.454Z Reference links |
Imported from gcve-enriched-dumps CVE data |
Contribute