Approved changes feed: RSS · Atom

cpe:2.3:a:fidelissecurity:network:9.4:*:*:*:*:*:*:*

part: a version: 9.4 update: *

VendorFidelissecurity (bb402e23-6dc0-5965-b13c-224d138fbaa0)
ProductNetwork (cd89c7d0-5343-59ec-98a6-7b242b33f3d1)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2021-35049 vulnerable 2026-06-08 05:32:17.566502 Command Injection Vulnerability in Fidelis Network and Deception
CRITICAL (9.9)
Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response in an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.3.7 and in version 9.4. Patches and updates are available to address this vulnerability.
Published: 2021-06-25T11:44:45.218Z
Updated: 2024-09-16T23:10:59.157Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2021-35048 vulnerable 2026-06-08 05:32:17.565997 Unauthenticated SQL Injection Vulnerability in Fidelis Network and Deception
CRITICAL (9.8)
Vulnerability in Fidelis Network and Deception CommandPost enables unauthenticated SQL injection through the web interface. The vulnerability could lead to exposure of authentication tokens in some versions of Fidelis software. The vulnerability is present in Fidelis Network and Deception versions prior to 9.3.7 and in version 9.4. Patches and updates are available to address this vulnerability.
Published: 2021-06-25T11:44:25.422Z
Updated: 2024-09-17T02:46:55.900Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2021-35047 vulnerable 2026-06-08 05:32:17.565386 Privileged Command Injection Vulnerability in Fidelis Network and Deception
CRITICAL (9.9)
Vulnerability in the CommandPost, Collector, and Sensor components of Fidelis Network and Deception enables an attacker with user level access to the CLI to inject root level commands into the component and neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.3.7 and in version 9.4. Patches and updates are available to address this vulnerability.
Published: 2021-06-25T11:44:30.916Z
Updated: 2024-09-16T20:41:47.623Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.