Schneider Electric Modicon M580 BMEH586040C
Approved changes feed: RSS · Atom
cpe:2.3:h:schneider-electric:modicon_m580_bmeh586040c:-:*:*:*:*:*:*:*
part: h version: - update: *
| Vendor | Schneider Electric (e6a779d5-aeb8-5b94-be36-761d5c05741c) |
|---|---|
| Product | Modicon M580 Bmeh586040C (0ae38bb3-910f-51ee-a5ef-60db2cd3ffa4) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2023-6408 |
not_vulnerable | 2026-06-08 06:19:47.324939 |
Details available
HIGH (8.1)
CWE-924: Improper Enforcement of Message Integrity During Transmission in a
Communication Channel vulnerability exists that could cause a denial of service and loss of
confidentiality, integrity of controllers when conducting a Man in the Middle attack.
Published: 2024-02-14T16:52:24.805Z
Updated: 2024-08-02T08:28:21.776Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-45789 |
not_vulnerable | 2026-06-08 05:50:36.830272 |
Details available
HIGH (8.1)
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)
Published: 2023-01-31T00:00:00.000Z
Updated: 2026-05-29T14:09:29.675Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-45788 |
not_vulnerable | 2026-06-08 05:50:36.724792 |
Details available
HIGH (7.5)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)
Published: 2023-01-30T00:00:00.000Z
Updated: 2026-05-29T14:08:52.615Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-37301 |
not_vulnerable | 2026-06-08 05:47:11.923918 |
Details available
HIGH (7.5)
A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU (part numbers BMXP34*)(V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*)(V3.22 and prior), Legacy Modicon Quantum/Premium(All Versions), Modicon Momentum MDI (171CBU*)(All Versions), Modicon MC80 (BMKC80)(V1.7 and prior)
Published: 2022-11-22T00:00:00.000Z
Updated: 2025-04-28T14:32:19.547Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-37300 |
not_vulnerable | 2026-06-08 05:47:11.876260 |
Details available
CRITICAL (9.8)
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
Published: 2022-09-12T17:40:10.000Z
Updated: 2024-08-03T10:29:20.628Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-22792 |
vulnerable | 2026-06-08 05:30:01.430896 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-22791 |
vulnerable | 2026-06-08 05:30:01.429281 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-22790 |
vulnerable | 2026-06-08 05:30:01.427656 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-22789 |
vulnerable | 2026-06-08 05:30:01.414214 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-22786 |
not_vulnerable | 2026-06-08 05:30:01.392140 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-22779 |
not_vulnerable | 2026-06-08 05:30:01.342640 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
Contribute