D-Link DIR-809
Approved changes feed: RSS · Atom
cpe:2.3:h:dlink:dir-809:-:*:*:*:*:*:*:*
part: h version: - update: *
| Vendor | Dlink (b610c9ff-f722-5d9d-a6df-9bee7f4d4b44) |
|---|---|
| Product | Dir 809 (c652ae8f-f6f0-5738-a24e-a3a73615bc0a) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2021-33274 |
not_vulnerable | 2026-06-08 05:32:11.037890 |
Details available
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80040af8 in /formWlanSetup. This vulnerability is triggered via a crafted POST request.
Published: 2021-12-01T21:20:51.000Z
Updated: 2024-08-03T23:42:20.269Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-33271 |
not_vulnerable | 2026-06-08 05:32:11.037570 |
Details available
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_80046EB4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request.
Published: 2021-12-01T21:20:52.000Z
Updated: 2024-08-03T23:42:20.417Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-33270 |
not_vulnerable | 2026-06-08 05:32:11.037077 |
Details available
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_800462c4 in /formAdvFirewall. This vulnerability is triggered via a crafted POST request.
Published: 2021-12-01T21:20:52.000Z
Updated: 2024-08-03T23:42:20.284Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-33269 |
not_vulnerable | 2026-06-08 05:32:11.036629 |
Details available
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualServ. This vulnerability is triggered via a crafted POST request.
Published: 2021-12-01T21:20:53.000Z
Updated: 2024-08-03T23:42:20.286Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-33268 |
not_vulnerable | 2026-06-08 05:32:11.036324 |
Details available
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_8003183C in /fromLogin. This vulnerability is triggered via a crafted POST request.
Published: 2021-12-01T21:20:54.000Z
Updated: 2024-08-03T23:42:20.363Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-33267 |
not_vulnerable | 2026-06-08 05:32:11.036006 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-33266 |
not_vulnerable | 2026-06-08 05:32:11.035667 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-33265 |
not_vulnerable | 2026-06-08 05:32:11.035231 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
Contribute