Approved changes feed: RSS · Atom

cpe:2.3:h:siemens:7kg9501-0aa01-2aa1:-:*:*:*:*:*:*:*

part: h version: - update: *

VendorSiemens (4bd2a91b-02ad-5c3d-b25f-70697e0c9d7f)
Product7Kg9501 0Aa01 2Aa1 (84ca71ac-647d-5e81-9b44-63a358610785)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2022-43546 not_vulnerable 2026-06-08 05:49:33.493514 Details available
CRITICAL (9.9)
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the EndTime-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.
Published: 2022-11-08T00:00:00.000Z
Updated: 2024-10-21T16:08:33.311Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-43545 not_vulnerable 2026-06-08 05:49:33.487901 Details available
CRITICAL (9.9)
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the RecordType-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.
Published: 2022-11-08T00:00:00.000Z
Updated: 2024-08-03T13:32:59.727Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-43439 not_vulnerable 2026-06-08 05:49:31.874929 Details available
CRITICAL (9.9)
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions < V2.50), SICAM P850 (7KG8500-0AA00-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA00-2AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA10-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA10-2AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA30-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA30-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA01-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA01-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA02-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA02-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA11-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA11-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA12-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA12-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA31-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA31-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA32-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA32-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA00-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA00-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA10-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA10-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA30-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA30-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA01-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA01-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA02-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA02-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA11-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA11-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA12-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA12-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA31-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA31-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA32-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA32-2AA0) (All versions < V3.10), SICAM T (All versions < V3.0). Affected devices do not properly validate the Language-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.
Published: 2022-11-08T00:00:00.000Z
Updated: 2025-12-09T10:44:06.193Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2022-43398 not_vulnerable 2026-06-08 05:49:31.771646 Details available
HIGH (7.5)
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user's account through the activated session.
Published: 2022-11-08T00:00:00.000Z
Updated: 2024-08-03T13:32:58.148Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2021-44165 not_vulnerable 2026-06-08 05:36:45.056943 Details available
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution.
Published: 2021-12-14T12:06:52.000Z
Updated: 2024-08-04T04:17:24.538Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.