Garrett iC Module CMA 5.0
Approved changes feed: RSS · Atom
cpe:2.3:o:garrett:ic_module_cma:5.0:*:*:*:*:*:*:*
part: o version: 5.0 update: *
| Vendor | Garrett (1af0d15c-0e7a-56b0-888a-165f71fc9025) |
|---|---|
| Product | Ic Module Cma (dddce8fa-3597-598e-97e8-61f1e30e0028) |
| Edition | * |
| Language | * |
| Software edition | * |
| Target software | * |
| Target hardware | * |
| Other | * |
| Notes | Imported from NVD CPE 2.0 feed |
PURL mappings
| PURL | Source | Last updated |
|---|---|---|
| No PURL mappings for this CPE yet. | ||
Vulnerability references
| Identifier | cpeApplicability | Submitted | db.gcve.eu details | Rationale |
|---|---|---|---|---|
CVE:CVE-2021-21907 |
vulnerable | 2026-06-08 05:29:13.391239 |
Details available
MEDIUM (4.9)
A directory traversal vulnerability exists in the CMA CLI getenv command functionality of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted command line argument can lead to local file inclusion. An attacker can provide malicious input to trigger this vulnerability.
Published: 2021-12-22T18:06:49.000Z
Updated: 2024-08-03T18:30:22.876Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-21906 |
vulnerable | 2026-06-08 05:29:13.390908 |
Details available
HIGH (8.2)
Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called “CMA Connect”, to interact with the iC Module on behalf of the user. Every time a user submits a password to the CLI password prompt, the buffer containing their input is passed as the password parameter to the checkPassword function.
Published: 2021-12-22T18:06:48.000Z
Updated: 2024-08-03T18:30:22.875Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-21905 |
vulnerable | 2026-06-08 05:29:13.390594 |
Details available
HIGH (8.2)
Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called “CMA Connect”, to interact with the iC Module on behalf of the user. After a client successfully authenticates, they can send plaintext commands to manipulate the device.
Published: 2021-12-22T18:06:47.000Z
Updated: 2024-08-03T18:30:23.083Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-21904 |
vulnerable | 2026-06-08 05:29:13.390271 |
Details available
CRITICAL (9.1)
A directory traversal vulnerability exists in the CMA CLI setenv command of Garrett Metal Detectors’ iC Module CMA Version 5.0. An attacker can provide malicious input to trigger this vulnerability
Published: 2021-12-22T18:06:46.000Z
Updated: 2024-08-03T18:30:23.143Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-21903 |
vulnerable | 2026-06-08 05:29:13.389945 |
Details available
CRITICAL (9.8)
A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to strcpy. An attacker can send a malicious packet to trigger this vulnerability.
Published: 2021-12-22T18:06:45.000Z
Updated: 2024-08-03T18:30:23.455Z |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-21902 |
vulnerable | 2026-06-08 05:29:13.389588 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2021-21901 |
vulnerable | 2026-06-08 05:29:13.389146 | db.gcve.eu details were skipped to keep the page responsive. | Imported from gcve-enriched-dumps CVE data |
Contribute
You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.