Approved changes feed: RSS · Atom

cpe:2.3:o:conceptronic:c54apm_firmware:1.26:*:*:*:*:*:*:*

part: o version: 1.26 update: *

VendorConceptronic (a40eec8a-a5ba-53c2-a9b3-073a3cbb3e0f)
ProductC54Apm Firmware (53ef41da-3b5f-5aa2-9125-25f59076cb42)
Edition*
Language*
Software edition*
Target software*
Target hardware*
Other*
NotesImported from NVD CPE 2.0 feed

PURL mappings

PURLSourceLast updated
No PURL mappings for this CPE yet.

Vulnerability references

IdentifiercpeApplicabilitySubmitteddb.gcve.eu detailsRationale
CVE:CVE-2014-1408 vulnerable 2026-06-08 05:05:24.522042 Details available
The Conceptronic C54APM access point with runtime code 1.26 has a default password of admin for the admin account, which makes it easier for remote attackers to obtain access via an HTTP request, as demonstrated by stored XSS attacks.
Published: 2014-01-10T16:00:00.000Z
Updated: 2024-08-06T09:42:35.414Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2014-1407 vulnerable 2026-06-08 05:05:24.521732 Details available
Multiple cross-site scripting (XSS) vulnerabilities on the Conceptronic C54APM access point with runtime code 1.26 allow remote attackers to inject arbitrary web script or HTML via (1) the submit-url parameter in a Refresh action to goform/formWlSiteSurvey or (2) the wlan-url parameter to goform/formWlanSetup.
Published: 2014-01-10T16:00:00.000Z
Updated: 2024-08-06T09:42:35.379Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2014-1406 vulnerable 2026-06-08 05:05:24.521391 Details available
CRLF injection vulnerability in goform/formWlSiteSurvey on the Conceptronic C54APM access point with runtime code 1.26 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via the submit-url parameter in a Refresh action.
Published: 2014-01-10T16:00:00.000Z
Updated: 2024-08-06T09:42:35.313Z
Reference links
Imported from gcve-enriched-dumps CVE data
CVE:CVE-2014-1405 vulnerable 2026-06-08 05:05:24.520465 Details available
Multiple open redirect vulnerabilities on the Conceptronic C54APM access point with runtime code 1.26 allow remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via (1) the submit-url parameter in a Refresh action to goform/formWlSiteSurvey or (2) the wlan-url parameter to goform/formWlanSetup.
Published: 2014-01-10T16:00:00.000Z
Updated: 2024-08-06T09:42:35.552Z
Reference links
Imported from gcve-enriched-dumps CVE data

Contribute

You can submit an edit proposal for this CPE entry or suggest a related product/vendor addition using the action button above.