CVE:CVE-2022-1525 |
not_vulnerable | 2026-06-08 05:39:13.362323 |
Cognex 3D-A1000 Dimensioning System Client-Side Enforcement of Server-Side Security
CRITICAL (9.1)
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-602: Client-Side Enforcement of Server-Side Security, which could allow attackers to bypass web access controls by inspecting and modifying the source code of password protected web elements.
Published: 2022-09-06T22:19:13.000Z
Updated: 2025-04-16T16:10:27.445Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-1522 |
not_vulnerable | 2026-06-08 05:39:13.356651 |
Cognex 3D-A1000 Dimensioning System Improper Output Neutralization for Logs
MEDIUM (5.3)
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics.
Published: 2022-09-06T22:19:13.000Z
Updated: 2025-04-16T16:10:35.734Z Reference links |
Imported from gcve-enriched-dumps CVE data |
CVE:CVE-2022-1368 |
not_vulnerable | 2026-06-08 05:39:12.813544 |
Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function
CRITICAL (9.8)
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
Published: 2022-09-06T22:19:13.000Z
Updated: 2025-04-16T16:10:43.133Z Reference links |
Imported from gcve-enriched-dumps CVE data |